Storage Heater vs. German Clay-Core Radiator Calculator
Compare indicative annual electricity costs for a room using a storage heater or a German Chamotte clay-core heater.
1. Adjust Room & Tariff Parameters
Indicative Matched Power Ratings:
Measure the heater body and compare its width with this guide.
Common older Dimplex XL/XLS sizes. Measure the case, not the clearance around it; other models may differ. The model label is the best way to confirm a heater’s rating.
Indicative estimate only. Storage charging is modelled at seven off-peak hours per heating day. The German heater is modelled at 20 minutes per heating hour after the room reaches temperature. Actual use and costs vary.
Annual Running Cost Comparison
| System | Rating | Annual kWh | Rate | Cost/yr |
|---|---|---|---|---|
| Night Storage | 1.70 kW | 2,142 kWh | 16.5p | £353 |
| German Clay Core | 1.50 kW | 720 kWh | 25.5p | £184 |
Storage use assumes the selected heater draws full rated power for seven off-peak hours on each heating day. German heater use assumes full rated power for 20 minutes in each selected heating hour. Heater sizes follow Elsco’s indicative room-volume bands; the Dimplex reference bands use a simplified 43 W/m³ estimate and are not official Dimplex room limits. The estimate excludes standing charges, warm-up, heat loss, weather, insulation and changes in occupancy. It is a guide, not a guarantee.
Across 15 years of installations, Elsco has often seen living rooms with a 3.4 kW (1,021 mm) storage heater that may be larger than the room needs. In those cases, potential savings may be higher than this size-matched estimate suggests. A larger German heater may instead warm the room faster and switch off sooner; this calculator does not model either effect or use the existing heater’s actual rating.
Need help sizing several rooms?
Room conditions vary. Contact Elsco for a room-by-room recommendation.
Request a heating assessmentThe really technical stuff
This calculator estimates the electricity use and running cost of one room under the schedule and tariff you enter. It is a scenario model, not a heat-loss survey or a promise of savings.
1. Room volume and heater sizes
Room volume is length × width × ceiling height. The area hint divides volume by 2.4 m; it is only a rough conversion and does not affect the heater size or result.
| Room volume | Elsco clay-core guide | Dimplex reference size |
|---|---|---|
| Up to 11 m³ | 0.50 kW | 1.70 kW |
| 12–17 m³ | 0.75 kW | 1.70 kW |
| 18–23 m³ | 1.00 kW | 1.70 kW |
| 24–35 m³ | 1.50 kW | 1.70 kW |
| 36–39 m³ | 2.00 kW | 1.70 kW |
| 40–47 m³ | 2.00 kW | 2.55 kW |
| 48–58 m³ | 2.50 kW | 2.55 kW |
| 59 m³ | Multiple; contact Elsco | 2.55 kW |
| 60–79 m³ | Multiple; contact Elsco | 3.40 kW |
| Above 79 m³ | Multiple; contact Elsco | Multiple; contact Elsco |
The clay-core bands follow Elsco’s supplied changeover points. Dimplex reference sizes use a simplified average heat-loss guide of about 43 W per m³ and the listed 1.70, 2.55 and 3.40 kW ratings. These are indicative volume matches, not official Dimplex room limits. Above 58 m³, the clay-core guide calls for multiple heaters and the calculator asks you to contact Elsco rather than extrapolating a cost.
The storage-heater width guide refers to common older Dimplex XL/XLS models: 1.70 kW is 565 mm wide, 2.55 kW is 793 mm wide and 3.40 kW is 1,021 mm wide. Measure the heater case itself; surrounding clearances are not included, and other models can have different dimensions.
2. Estimated annual electricity
- Storage heater: selected storage rating (kW) × 7 off-peak hours per heating day × heating days per year.
- German clay-core heater: selected rating (kW) × ⅓ hour per heating hour × heating hours per day × heating days per year. One third of an hour represents the assumed 20-minute on-time in each heating hour.
For the default 35 m³ room, the model selects a 1.70 kW storage heater and a 1.50 kW clay-core heater. At 8 hours a day and 180 days a year, that gives 2,142 kWh for storage and 720 kWh for the clay-core estimate.
3. Tariffs, costs and displayed difference
Each annual kWh estimate is multiplied by its entered rate in pence per kWh and divided by 100 to convert pence to pounds. At the default rates, 16.5p/kWh for storage and 25.5p/kWh for the clay-core heater, the estimates are £353.43 and £183.60. The displayed difference is storage cost minus clay-core cost: £169.83, rounded to £170. When the clay-core estimate is lower, the percentage is the difference divided by the storage cost; otherwise the calculator reports the extra cost for that scenario.
Costs and energy use are rounded to the nearest whole pound and kWh for display. Standing charges and equipment or installation costs are excluded.
4. What this model does not account for
It assumes seven full-power hours of storage charging on every heating day and a 20-minute-per-hour clay-core duty cycle during the selected heating hours. It does not model warm-up, actual thermostat cycles, heat lost from stored energy, room insulation, outside temperature, controls, occupancy changes or differences between individual products and homes. Your actual consumption and tariff can produce a different result.
5. Heater sizing and oversizing
Across 15 years of installations, Elsco has often observed living rooms fitted with a 3.4 kW (1,021 mm) storage heater where a smaller heater may have been sufficient. If the existing storage heater is larger than the reference size selected here, its actual consumption may exceed this estimate, so potential savings from replacing it may be higher. The calculator does not ask for the installed heater’s actual rating or use meter readings.
A German heater with more capacity than the room needs may reach the thermostat setting sooner and switch off earlier. A higher rated output does not mean it runs continuously at that output. The calculator still applies its fixed 20-minute-per-hour assumption, so it does not calculate faster warm-up or shorter cycles for an oversized German heater.